It also allowed them to build a model predicting return on investment of the renovation through the energy cost savings to be realized. enteliWEB version 4. The Energy view product and demand charts then allowed them to view energy trends in the building and CopperTree’s customizable reports gave them the ability to pinpoint which equipment and systems could deliver the most energy-savings impact. To investigate the building and establish a baseline, trend logs were then processed by CopperTree’s Kaizen, a powerful analytics engine and logic builder. South Florida Controls used CopperTree Analytics’ CopperCube to extract current and historical trend logs from the building automation system. It also provided the building management a tool to monitor energy usage in the future. This established the building’s baseline consumption and potential energy reductions to be realized as a result of the renovation. Then South Florida Controls used CopperTree trend logs and reports to model the projected energy savings and ROI. The next step is to configure Kaizen server for your site.South Forida Controls used CopperTree Analytics to study the building and identify which equipment, systems and structures could have the most energy-saving impact. Your CopperCube has now been configured to start collecting data from the BACnet network. To select which trend log you wish to collect, use the steps here: * Trend Log Selection* Trend Log information can also be sent to a local SQL database.Īfter the CopperCube has completed a network discovery to find all the BACnet Devices and associated objects, you need to specify which Trend Logs you wish to collect and store in the CopperTree Vault. The Device Ranges settings enables you to set a range of devices for the CopperCube to monitor for collecting Backups, Trend Logs, and other BACnet objects to sent the the CopperTree Kaizen Vault. (Note: CopperCube 1.4 version has the Sites and Device Ranges in two separate pages)Ĭlicking on '+Add' will direct you to this page below. This site name will also need to be entered into Kaizen so that your Kaizen account presents the correct data. See Sites for information on defining your site(s).
Coppertree coppercube software#
The site provides a definition for the CopperCube software to be able to connect to the BACnet network and retrieve data. You must have the CopperCube connected by the BACnet port to the building controls network to configure the Sites and Devices.
Coppertree coppercube how to#
LAN 2 - Service Port - the IP address for this port is configured at the factory with a static IP address: 169.254.8.29 and cannot be changed.This address is part of the reserved 'zero configuration IP' address range (.x).Īs the configuration of a CopperCube is done via a web browser, it is recommended to use a Static IP address for the BACnet port.įollow the instructions at How to set IP Settings for information on how to configure these settings.LAN 1 - BACnet Port - can be configured by the user to have a dynamic IP address or a user defined static IP address.The CopperCube comes pre-configured with two active Ethernet ports: The Time Zone and Header Logo settings are one that are recommended to be updated. The Basic Settings page is used to do some configuration of the CopperCube. Below are the steps for configuring your CopperCube: You have to configure the CopperCube so that it can start sending data to the secure cloud. If you are logging into the CopperCube for the first time, see the image below for username and password. The CopperCube GUI requires the user to log in using a username and password. If the setup is correct, you should see the status page of the CopperCube graphical user interface (UI). Open a web browser and enter 169.254.8.29 into the address bar.Please note that the CopperCubes purchased prior to Mahas a different fixed-IP. Plug a Cat5e cable into your computer's network port and then into and into the CopperCube fixed-IP Service port (labelled LAN 2).When the CopperCube starts up, it will produce a short beep. Check the Power LED and if it is not on, press and hold the power button until the green power light turns on.Part numbers are 194300 (North America) and 194301 (European) If you did not order a power supply and require one, they are available through online ordering. Connect 24VAC/50VA to the 2-pin screw terminal or 12-28VDC/30W through the barrel connector of a power supply to the CopperCube.This document describes the steps that need to be done in order to set up your CopperCube so that it can collect data from your BACnet network. Your CopperCube has come from the factory in an unconfigured state.